How It Works

PurePAP™ comes ready to use right out of the box! With just three simple steps, you’ll be cleaning your CPAP equipment quickly and easily.


1. Connect Your Hose to PurePAP™

Disconnect your hose from your CPAP machine and connect it to the hose connector on PurePap™. Keep your mask connected to the other end of the hose.


A universal adapter is provided for connecting heated tubes to PurePap.


2. Place All Components Inside the Sanitizing Zip Bag

Place your mask and hose that’s connect to the PurePAP into the sanitizing zip bag. Zip up the bag tightly.


Empty out your water chamber and place inside the bag.


Its recommended you clean your water chamber once per week.


3. Press the Start Button

Hold down the power button for five seconds to turn on the PurePap device. It will automatically go into timer-mode. The cleaning cycle will run for 30 minutes, after which you will hear a beep sound and the device will turn off automatically.


It is recommended to keep all components in the bag an hour after the cleaning cycle is over to make sure all activated oxygen (ozone) is converted back to Oxygen (O2).


It’s That Easy!

Instructions

User Manual

CPAP/APAP/BI-PAP Sanitizer

HOW TO USE PUREPAP®

User Manual: CPAP/APAP/BI-PAP Sanitizer

STEP 1:

Unplug the CPAP tube from your CPAP machine. Connect it to the valve on the PurePAP™.


*If using a heated tube or smaller tube for (Philips Dreamstation etc) then a tube connector may be needed to connect to the PurePAP™device.

STEP 2:

Place the mask and connected tubing along with the water chamber inside the sanitizing zip bag. Zip the bag closed.


*Make sure the water chamber has been emptied and dried before placing inside the bag. The tubing should remain connected to the face mask inside the bag. Be sure to zip the bag all the way closed.


*Make sure to close the USB cover before placing PurePAP® inside the bag.

STEP 3:

Hold down the power button from outside the bag for 3 seconds to start the device. That's it. Come back in 1 hour and 30 minutes to find your PAP components clean and ready to use!



Note: The included T-adapter and clear flexible hose accessories are included to clean unremovable water chambers.

Hold down the power button until you hear a "beep" sound and see the screen turn on the PurePAP™ device. The device will automatically be set to 30-minute cleaning cycle. We recommend leaving the bag closed for 1 hour after the cleaning is completed to let any remaining odor dissipate. Then unzip the bag to find your CPAP equipment ready to use. The device will shut off automatically after the cycle is finished. There is no need to watch your PurePAP™ !


Charging your PurePAP™ Device: When the device is connected to the charger, the device will beep once, and a red light will appear. The light will turn green once it's completely charged.


LOW BATTERY: The device will beep 5 times every 10 seconds when there is low battery. The device will still run on low battery but may not complete a full cycle, only when the battery is completely drained will the device not turn on.


You cannot overcharge your PurePAP.

Device Modes

What's Inside: PurePAP™ Device, Sanitizing Zip Bag, Travel & Storage Bag, A/C Adapter, USB Charging Cord, (2) Universal Tube Adapters, (5) Additional Activated Charcoal Filters, Flexible Hose

PurePAP™ has three disinfection modes: 20 minutes, 30 minutes, and 40 minutes.


Turning PurePAP™ on enters into default mode of 30 minutes; press the power button once to switch between the three modes.


20-minute mode includes 10 minutes ozone disinfection and 10 minutes fresh air cycle.


30-minute mode includes 20 minutes ozone disinfection and 10 minutes fresh air cycle.


40-minute mode includes 25 minutes ozone disinfection and 15 minutes fresh air cycle.


Turn Off Device: Hold down the power button for 5 seconds, until the light on the device shuts off and a beep sound is made.


Recommendation: Use the default 30-minute mode for the mask & hose. If solely cleaning a mask, then 20-minute mode will be sufficient. If mask, hose and water chamber are being sanitizing together, 40-minute mode is advised.

CHARCOAL FILTER REPLACEMENT
PurePAP® comes with a charcoal filter to help eliminate dust and odor during the sanitization cycle. This charcoal filter is recommended to be replaced every 2-3 months if PurePAP is used daily.



Replacing Charcoal Filter:

  1. Remove the screw with a screwdriver.
  2. Remove the filter cover.
  3. Replace the old filter with the new filter.
  4. Reassemble the filter cover with the screw.

Indications of Use, Cautions, & Specifications

PurePAP ™ is designed to sanitize continuous positive airway pressure (CPAP) mask, hose, and water chamber all at once using activated oxygen (03) which kills germs and bacteria. It is recommended to sanitize your mask and hose daily, and the water chamber weekly.


Electrical & Environmental Characteristics:

Power Consumption: 5W Max

Battery: 1 lithium ion battery, 2500 mAh. UL listed.

Adapter input: AC 100 ~ 240V, 50/60HZ

Adapter output: 5.0V

Storage temperature: 32 °F to 131 °F

Operating temperature: 50 °F to 100°F

Package Weight: 1.6Ibs

Air Flow: 5.06CFM

Operating Cycle: 20-40 minutes


CLASSIFICATION: US FDA Class 1 per 21 CFR 880.6890-General purpose disinfectants

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.



CAUTION: Keep PurePAP™ inside the zip bag, do not run the device outside of the closed zip bag.

CAUTION: Do not breathe directly from PurePAP™ , at increased concentrations of ozone in the air produced by PurePAP™ is harmful to health.

CAUTION:Keep away from water sources.

CAUTION: Never use PurePAP™ in confined spaces less than 100 square foot room with 7" ceiling.CAUTION: Keep away from children. It is not a toy.

CAUTION: Never use PurePAP™ when it's outside of Cleaning Zip Bag. If a strong ozone odor is detected when PurePAP™ is operating, turn off PurePAP™ by holding down power button for 2 seconds. Check hose connections and make sure there are no cracks in the housing, CPAP hose and hose adapters.

CAUTION: Person's with acute or chronic respiratory conditions such as asthma, bronchitis and sensitive or irritated breathing passages (mouth, nose, throat) should consult with their medical doctor before using this product.

CAUTION:: Keep away from flammable gasses and chemicals.

CAUTION: Discontinue use of PurePAP™ if acne or rash develops along mask contact line .

CAUTION: Keep away from children.

CAUTION: Do not place any items on top of your PurePAP or bag, particularly flammables or ignitable items.

CAUTION: Do not dismantle the PurePAP device.

CAUTION: Do not run the PurePAP device for more than one 40-minute cycle consecutively.

CAUTION: PurePAP device can be cleaned using a damp cloth.


Model No: S500

Kills 99% of Bacteria & Germs

Rechargable • Portable • Lightweight • Quiet
For Only: $199.95
Save $100 With Instant Rebate!
NOW JUST $99.95 + S/H